Sentron Angle Sensor, Linear 2-Axis Hall IC, 2SA-10
|
| |
| Absolute
Maximum Ratings |
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Remarks |
| Supply
Voltage |
Vsup |
0 |
- |
6.0 |
V |
|
| Operating
Temperature |
T |
-40 |
- |
125 |
°C |
|
| Storage
Temperature |
Ts |
-40 |
- |
150 |
°C |
|
| Recommended
Operating Conditions |
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Remarks |
| Supply
Voltage |
Vsup |
4.5 |
5 |
5.5 |
V |
|
| Output
Current |
Iout |
-1 |
- |
1 |
mA |
|
| Load
Capacitance |
CL |
-
|
- |
1000 |
pF |
|
Electrical
Characteristics
At
T=-40°C to +150°C, Vsup=4.5V to 5.5V if not otherwise
specified. |
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Conditions |
| Supply
Current |
Isup |
- |
12 |
18 |
mA |
|
Common
Reference
Output Voltage1 |
VCommon |
Vsup/2
-20mV |
Vsup/2 |
Vsup/2
+20mV |
V |
Iout=0mA |
| Bandwidth |
BW |
10 |
15 |
18 |
kHz |
|
Magnetic
Input Conditions
At
T=-40°C to +150°C, Vsup=4.5V to 5.5V if not otherwise
specified. |
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Conditions |
| Maximum
Field |
BMax |
-
|
- |
80 |
mT |
|
Diameter
of Magnetic
Disc |
Dfc |
- |
0.2 |
- |
mm |
|
| Angular
Speed |
w |
- |
- |
100,000 |
rpm |
|
Analog
Output Characteristics2
At
T=-40°C to +150°C, Vsup=5.0V if not otherwise
specified. |
| Magnetic
Sensitivity1 |
S |
40 |
50 |
60 |
V/T |
|
Magnetic
Sensitivity
Temperature Drift1 |
S/S T |
-0.05 |
- |
+0.05 |
%°C |
Iout=0mA
T=-40 - +150°C |
Magnetic
Sensitivity
Missmatch (X-Y) |
Sx/Sy |
- |
0 |
2.0 |
% |
B=50mT |
| Phase
Matching |
Sx-Sy |
-0.3 |
0 |
+0.3 |
° |
B=±50mT |
| Offset
Voltage |
Voff |
-10 |
0 |
+10 |
mV |
B=0,
Iout=0mA,
T=-20 - +80°C |
Offset
Temperature
Drift |
Voff/ T |
-0.05 |
0 |
+0.05 |
mV/°C |
B=0,
Iout=0mA |
Full
Scale Magnetic
Field Range |
Bfs |
-45 |
- |
+45 |
mT |
S=50V/T |
Linear
Magnetic Field
Range |
BL |
-40 |
- |
40 |
mT |
S=50V/T |
| Non
Linearity |
NL |
|
0.1 |
0.2 |
% |
B=±40mT |
Input
Refered Magnetic
Noise Spectrum
Density (RMS) |
Bnoise |
|
|
750 |
nT/ Hz |
F=1Hz
to 10kHz |
1.
Ratio-metric (proportional to Vsup)
2. When the analog pins Xout and Yout are used in differential
mode. (i.e. Vx = x_out - co_out)
Test
Circuit:
Package:
SOIC-8
|
Pin
out:
1) CO_OUT - Common Output
2) PC - Programming Clock1
3) VDD (Vsup) - Positive Supply Voltage
4) Y_OUT - Y Axis Analog Output
5) X_OUT - X Axis Analog Output
6) PD - Programming Data1
7) PV - Programming Voltage1
8) Gnd - Voltage Ground |
1.
Used for factory programming of the 2SA-10.
Note
The preprogrammed data of the sensors are stored in an
internal shift register. Strong electrostatic discharges
may change the programmed parameters. To help protect
the sensors from such disruption please follow the guidelines
below when installing the sensors.
Place a capacitor between VDD and GND in close
proximity to the sensor.
Use shielded, twisted pair cables whenever possible.
Use a good power supply with adequate EMI protection.
Connect the sensor programming voltage and clock
inputs to VDD. Connect the programming data input to GND.
Specifications subject to change without notice.
Sentron roducts are not to be used in devices or assemblies if the failure in any way of the Sentron
product could cause that device, assembly or associated system to become hazardous or unsafe.
Last updated on
20 July, 2007
|
| Back