Magnetic Field Mapper, MMS-1A-RS

Magnetic Field Mapping System MMS-1A-RS allows a user to create high resolution map of the magnetic field around an electromagnet or permanent magnet. The map of the magnetic field may be given in the form of color coded 2D or 3D isometric visual display on PC screen, tables of the numerical values of the three components, the total magnetic field, and so on. Due to the unique features of the applied integrated Hall probe, all three components of the magnetic field are measured simultaneously at virtually the same point. The system is controlled by an extremely easy-to use-software built on MS Windows platform.

Typical Applications

  • Quality control of permanent magnets;
  • Quality assessment tool in production, for assemblies such as loudspeakers, multi-pole magnets, photocopier rollers and magnetic film;
  • Development of magnet systems;
  • AC magnetic field mapping;
  • Application in laboratories and in production lines, etc.

Additional Information

  1. Senis Magnetic Measurement Product Guide
  2. Integrating Magnetic Field Mapping Crack Detection and Coordinate Measurement Presentation

Overview

Model MMS-1A-RS
Scanning Volume (135 x 135 x 135 mm (standard); up to (500 x 500 x 500 mm) optional.
Scanning Spatial Resolution 1 µm
Scanning Speed, Adjustable Up to 100mm/sec
Magnetic Field Measurement Accuracy typically 0.1%
Magnetic Field Range ±20mT, ±200mT, ±500mT, ±1000mT, ±2000mT
DC and AC Magnetic Field Bandwidth DC to 2.5 kHz (standard); DC to 25kHz (3-axis, optiona); DC to 75 kHz (1-axis optional)
Rotating Stage Standard
Non-magnetic Multi-jaw Scroll Chuck Standard
Touch Sensor to Protect Prob Standard; Add-on stylus and software for dimensional measurement (optional)

Accessories

ZG7 - Zero Gauss Chamber

Used for zeroing the reading.
Dimenisons: 27mm OuterDiameter, 21mm Inner Diameter, 68mm Length.
Shielding Factor: 100

MMS-SC Non-Magnetic multi jaw scroll chuck

For percise holding of magnet under test.
Especially conveniet for ring and cylindrical magnets.

MMS-RS Rotating Stage

Mounted to mapper table
MMS-1A-RS includes rotery encoder along with MMS-RS

MMS-CT

Calibration tool for hall probe field sensitive area calibration. Consists of corrat conducting copper layer on PcB, constant current supply, and sottucre module for autmatic calibration. Also incldues MMS-MF

MMS-MF

Magnet frame for absolute positioning. Convenient for rectangular magnet samples

MMS-Safety Cabinet

Protect cabinet with emergency stop. Required for EU safety regulation-CE directives.

MMS-Saftey Cabinet Acrylic

Safety cabinet made with antistatic Acrylic sheets. Required for QA mapper applications in production lines.

Touch Sensor

Prevents probe damage. It serves as emergency stop which is triggered whenever object is touched by probe.

Touch Sensor CMM

Upgrade to touch sensor for coordinate measurement (dimensional measuring). Consists of Add-on saphire-tipped stylus and cmm software.

Pricing

Part No. Description Qty Price
MMS-1A-RS

Magnetic Field Mapper, 3-Axis, typically 0.1% Field Accuracy, 1µm resolution, 135x135x135mm Cartesian Moving Platform (CMP). Scanning volume: 125 x 125 x 150mm (x,y,z).

Includes:

  • F3A Three-Axis Magnetic Field Transducer.
    • Specify Type KM, Type HM, or Type HL.
    • Specify one full-scale field range from either group1:
      • 100mT, 500mT, 2T.
  • Cartesian Moving Platform. Maximum scanning speed 100mm/sec. Includes Probe Holder. Includes optical boundary switches to obtain probe position, and mechanical switches to prevent damage to linear modules.
  • Stepper Motor Drivers (SSMD)
  • Linear Encoders for linear axes (x,y,z) for 1µm resolution.
  • Emergency Stop Safety Switch
  • NI Motion Controller for simultaneous control of four axes (x,y,z,t). Allows for higher scanning speeds (100mm/s) and complex scanning paths (circles, 3D contours, etc.).
  • Multifunctional NI DAQ for Motor Drive Control and Data Acquisition. Connects to PC via USB interface.
  • MMS-RS Rotating Stage With Rotary Encoder (resolution 0.022 degrees)
  • MMS-SC Non-magnetic scroll chuck.
  • MMS-TS Touch sensor to prevent probe damage. Triggers emergency stop whenever probe touches an object under measurement process.
  • MMS-CT Calibration Tools. Includes MMS-MF magnet frame.
  • MMS-Analysis. Mapper Software module for user-defined data visualization and analysis.
  • DELL or HP desktop computer with Windows Professional OS and Senis Mapping Software.
  • MMS-ZG7 Zero Gauss Chamber. Magnetic Shield for correcting the probe zero field offset.
  • Power Supply
  • Documentation
  • Installation, supervision & training at the customer’s site in North America – 2 full days
  • Warranty of 12 months from customer’s site acceptance
$104,250.00
Description

Magnetic Field Mapper, 3-Axis, typically 0.1% Field Accuracy, 1µm resolution, 135x135x135mm Cartesian Moving Platform (CMP). Scanning volume: 125 x 125 x 150mm (x,y,z).

Includes:

  • F3A Three-Axis Magnetic Field Transducer.
    • Specify Type KM, Type HM, or Type HL.
    • Specify one full-scale field range from either group1:
      • 100mT, 500mT, 2T.
  • Cartesian Moving Platform. Maximum scanning speed 100mm/sec. Includes Probe Holder. Includes optical boundary switches to obtain probe position, and mechanical switches to prevent damage to linear modules.
  • Stepper Motor Drivers (SSMD)
  • Linear Encoders for linear axes (x,y,z) for 1µm resolution.
  • Emergency Stop Safety Switch
  • NI Motion Controller for simultaneous control of four axes (x,y,z,t). Allows for higher scanning speeds (100mm/s) and complex scanning paths (circles, 3D contours, etc.).
  • Multifunctional NI DAQ for Motor Drive Control and Data Acquisition. Connects to PC via USB interface.
  • MMS-RS Rotating Stage With Rotary Encoder (resolution 0.022 degrees)
  • MMS-SC Non-magnetic scroll chuck.
  • MMS-TS Touch sensor to prevent probe damage. Triggers emergency stop whenever probe touches an object under measurement process.
  • MMS-CT Calibration Tools. Includes MMS-MF magnet frame.
  • MMS-Analysis. Mapper Software module for user-defined data visualization and analysis.
  • DELL or HP desktop computer with Windows Professional OS and Senis Mapping Software.
  • MMS-ZG7 Zero Gauss Chamber. Magnetic Shield for correcting the probe zero field offset.
  • Power Supply
  • Documentation
  • Installation, supervision & training at the customer’s site in North America – 2 full days
  • Warranty of 12 months from customer’s site acceptance
Qty

Cartesian Moving Platform (CMP) and Overall Mapper System Options

MMS-CMP135x135x300

Extended Cartesian Moving Platform, 135 x 135 x 300mm. Scanning Volume:  125 x 125 x 290 mm (x,y,z).

$13,610.00
Description

Extended Cartesian Moving Platform, 135 x 135 x 300mm. Scanning Volume:  125 x 125 x 290 mm (x,y,z).

Qty
MMS-CMP500x500x300

Extended Cartesian Moving Platform, 500 x 500 x 300mm. Scanning Volume:  570 x 570 x 290 mm (x,y,z).

$29,930.00
Description

Extended Cartesian Moving Platform, 500 x 500 x 300mm. Scanning Volume:  570 x 570 x 290 mm (x,y,z).

Qty
MMS-CMP500x500x500

Extended Cartesian Moving Platform, 500 x 500 x 500mm. Scanning Volume:  570 x 570 x 380 mm (x,y,z).

$35,910.00
Description

Extended Cartesian Moving Platform, 500 x 500 x 500mm. Scanning Volume:  570 x 570 x 380 mm (x,y,z).

Qty
MMS-CMP(XXxYYxZZ)

Extended Cartesian Moving Platform, Custom dimensions. Inquire for details.

Ask
Description

Extended Cartesian Moving Platform, Custom dimensions. Inquire for details.

Qty
MMS-LMF

Mapper adaptation required for low magnetic field testing (<100nT), such as no magnetic materials in touch sensor, mapper mechanical parts, etc

$29,930.00
Description

Mapper adaptation required for low magnetic field testing (<100nT), such as no magnetic materials in touch sensor, mapper mechanical parts, etc

Qty
MMS-CleanRoom

Mapper adaptation required for Class 100 Cleanroom compatibility (HEPA filter, fans, cleanroom compatible materials, etc.)

$29,930.00
Description

Mapper adaptation required for Class 100 Cleanroom compatibility (HEPA filter, fans, cleanroom compatible materials, etc.)

Qty
MMS-IO

Additional analog/digital inputs/outputs (5V/100mA) for integrating customer’s probes (up to 8). Measurement range for digital input 0-5V, for analog input +/-10V, 16 bit resolution.

$3,750.00
Description

Additional analog/digital inputs/outputs (5V/100mA) for integrating customer’s probes (up to 8). Measurement range for digital input 0-5V, for analog input +/-10V, 16 bit resolution.

Qty

Probe Options

MMS-MR2

Second measurement range for the 3-axis Magnetic Field Transducer1

$3,750.00
Description

Second measurement range for the 3-axis Magnetic Field Transducer1

Qty
MMS-MR3

Second and third measurement range for the 3-axis Magnetic Field Transducer1

$4,490.00
Description

Second and third measurement range for the 3-axis Magnetic Field Transducer1

Qty
MMS-SP-H

Spare H-Module (probe) of the 3-axis Magnetic Field Transducer. Highly recommended; mandatory for QA mapper applications in production lines. See Senis Transducers F3A Series overview.

$5,240.00
Description

Spare H-Module (probe) of the 3-axis Magnetic Field Transducer. Highly recommended; mandatory for QA mapper applications in production lines. See Senis Transducers F3A Series overview.

Qty
MMS-SP-E

Spare E-Module (Electronics, S-Type) of the 3-axis Magnetic Field Transducer.
See Senis Transducers F3A Series overview

$5,240.00
Description

Spare E-Module (Electronics, S-Type) of the 3-axis Magnetic Field Transducer.
See Senis Transducers F3A Series overview

Qty
MMS-CMM

System for dimensional measurement of objects under test (easy-to-use-CMM). Consist of stylus mounted to MMS-TS and software module.

$8,980.00
Description

System for dimensional measurement of objects under test (easy-to-use-CMM). Consist of stylus mounted to MMS-TS and software module.

Qty
MMS-AMR

3-axis, high-resolution AMR Probe (dimensions: 7.37 x 7.27 x 2.5mm) connected to the lownoise transducer. Magnetic field range: 0.5mT; Magnetic resolution: better than 100nT; Accuracy: better than 200nT.

$14,970.00
Description

3-axis, high-resolution AMR Probe (dimensions: 7.37 x 7.27 x 2.5mm) connected to the lownoise transducer. Magnetic field range: 0.5mT; Magnetic resolution: better than 100nT; Accuracy: better than 200nT.

Qty
MMS-CMM-SP-P

Adapter for the spare probe (H-module). Not required if MMS-CMM option is also ordered.

$2,250.00
Description

Adapter for the spare probe (H-module). Not required if MMS-CMM option is also ordered.

Qty
MMS-DEF

Eddy-current system (Defectoscope) for system inhomogeneity and crack detection in magnetized and non-magnetized materials.

$14,690.00
Description

Eddy-current system (Defectoscope) for system inhomogeneity and crack detection in magnetized and non-magnetized materials.

Qty
MMS-SLID

Sliding probe for in-contact measurement (less than 100um from the sample surface).

$10,480.00
Description

Sliding probe for in-contact measurement (less than 100um from the sample surface).

Qty

DUT (Device under Test) Handling Options

MMS-ATP

Axial Tilt Platform for MMS-RS Rotary Stage and MMS-SC Scroll Chuck, Manual Adjustment. X&Y, +/-2mm, +/-0.04mm; Tilt +/- 0.6°, +/- 0.02°.  200N (45lbf) max.

$11,230.00
Description

Axial Tilt Platform for MMS-RS Rotary Stage and MMS-SC Scroll Chuck, Manual Adjustment. X&Y, +/-2mm, +/-0.04mm; Tilt +/- 0.6°, +/- 0.02°.  200N (45lbf) max.

Qty

Safety Options

MMS-SafetyCabinet

Protective cabinet with emergency stop. Required for EU Safety refulations – CE directives.

$5,240.00
Description

Protective cabinet with emergency stop. Required for EU Safety refulations – CE directives.

Qty
MMS-SafetyCabinetAcrylic

Protective cabinet made with anti-static Acrylic Sheets with emergency stop. Required for EU safety regulation – Cedirectives. Mandatory for QA Mapper application in production lines.

$9,730.00
Description

Protective cabinet made with anti-static Acrylic Sheets with emergency stop. Required for EU safety regulation – Cedirectives. Mandatory for QA Mapper application in production lines.

Qty
MMS-SafetyCurtains

Safety Light Curtains (for European safety regulations – CE directives). Mandatory for QA Mapper applications in the production lines.

$5,990.00
Description

Safety Light Curtains (for European safety regulations – CE directives). Mandatory for QA Mapper applications in the production lines.

Qty

Other Accessories

MMS-ZG7

Spare Zero Guass Chamber. Magnetic shield of correcting probe zero field offset.

$530.00
Description

Spare Zero Guass Chamber. Magnetic shield of correcting probe zero field offset.

Qty
MMS-PC-IND

Industrial PC for more Reliable Operation

$5,990.00
Description

Industrial PC for more Reliable Operation

Qty
MMS-STYLUS

Touch stylus ruby ball for Calibration Cube alignment

$2,250.00
Description

Touch stylus ruby ball for Calibration Cube alignment

Qty
RPM-0.1T or RPM-0.05T

Reference Permanent Magnet (0.1T or 0.05T) for probes validation

$5,240.00
Description

Reference Permanent Magnet (0.1T or 0.05T) for probes validation

Qty
MMS-Cal

Hall probe calibration tool for in-situ calibration of the Hall probe’s sensitivity matrix. Specify field of 0.1T, 0.05T or 1mT for Calibration tool.

$6,810.00
Description

Hall probe calibration tool for in-situ calibration of the Hall probe’s sensitivity matrix. Specify field of 0.1T, 0.05T or 1mT for Calibration tool.

Qty
MMS-Service

Annual service, per year, up to 5 years after installation. Includes transducer calibration, mapper software updates, up to one-week on-site support and response within 3 hours (swiss working hours). Price is 16% of Full Price

Ask
Description

Annual service, per year, up to 5 years after installation. Includes transducer calibration, mapper software updates, up to one-week on-site support and response within 3 hours (swiss working hours). Price is 16% of Full Price

Qty

1 Measurement ranges can be grouped by Resolution.
Highest resolution: 20, 50 or 100mT
High resolution: 200 or 500mT
Standard resolution: 1T, 2T or 3T.

When ordering multiple range probes (MR2, MR3 or MR4 option), it’s generally best to select  ranges from different resolution categories.

To request a Returned Material Authorization number (RMA), please email rma@gmw.com. Please include full details.

Terms and Conditions

Terms and Conditions:

Prices above are for domestic deliveries to Canada, USA and Mexico only.
Prices are expressed in U.S. Dollars, FCA San Carlos, California.
Prices are subject to change without notice.

Payment:

Visa, MasterCard, Amex, Prepayment before shipment, or Net 30 days (subject to credit acceptance).

Delivery:

Stock to 120 days, depending on model and quantity.