Senis Magnetic Field Transducers, YM12  
Tabs
 
Senis YM12 Magnetic Field Transducers are no longer in production. Review and consider Senis I1A Low Noise Magnetic Field Transducers.

Specifications - YM12-3-2-0.2T & YM12-3-2-2T
 Electrical Characteristics
  Model Number YM12-3-5-0.2T YM12-3-5-2T YM12-3-5-5T

  Full-Scale Field (Max)

±0.2T (±0.4T)

±2.0T (±4.0T)
±5.0T
  Differential Voltage Outputs: (Bx, By, & Bz) ±10.0V
  Sensitivity 50V/T (5mV/G) 5V/T (0.5mV/G) 2V/T (0.2mV/G)
  Accuracy ±0.1% (B=0.1T) ±0.1% (B=1T) ±0.1% (B=1T)
  Non-Linearity <1% (B=0.2T) <1% (B=2T) <2% (B=5T)
  Long Term Stability <1%/10 years
  Temperature Coefficient of Sensitivity <100ppm/°C
  Offset (B=0T) ±10mV (±2G) ±1mV (±2G) ±0.5mV (±2.5G)
  Temperature Coefficient of Offset (B=0T) <1mV/°C (0.2G) <0.1mV/°C (0.2G) <0.1mV/°C (0.5G)
  Output Noise and Ripple (Peak, 0.01 to 100Hz) <±0.5mV (±0.1G) <±0.06mV (±0.12G) <±0.05mV (±0.2G)
  Output Resistance (Short Circuit Protected) <10W
  Frequency Response
    1% Error
    -3dB

>1kHz
5kHz
  Temperature
    Operation (within spec.)
    Storage

10 to 50°C
-20 to 85°C
  Power ±12V, 50mA
 Mechanical 
  Electronics (Module E) 
   Connectors
     Power
     Signal Output

DIN SFV50, 5 Pole
DIN KFV70, 7 Pole
   Dimensions (mm) 95 x 120 x 37
   Weight
    Module E
    Signal Output Cable

470g
43g/m
   Material Aluminum
  Probe (Module H)
   Dimensions (mm) 5.0 x 2.0 x 14.0mm
   Weight
     H-Module (field sensor)
     H-Module to E-Module Cable

2g
42g/m
   Material Ceramic with Epoxy Cap
   Field Sensitive Volume (Dx, Dy, Dz) 0.125 x 0.10 x 0.125mm
   Center of the Field Sensitive Volume 2.5 x 1.45 x -1.0mm
   Angular Accuracy of the Axis
     To the Reference Ceramic

±0.5°
   Cable Length
     Standard
     Maximum

5 meters
10 meters
 Electromagnetic Testing
  RF Conducted Disturbances: IEC/EN 61000-4-6, ENV 50141
  Radiated Electromagnetic Field: ENV 50140
  Pulse Modulated Electromagnetic Field: ENV 50140
  Electrical Fast Transient Burst: IEC/EN 61000-4-4
  Electrostatic Discharge: IEC/EN 61000-4-2*
 
 Test Conditions:
  The transducer was tested using Senis 'S12' power supply, which conforms to the directives 73/23/EEC and 89/336/EEC.
The output cable used was Senis 'CO15' shielded output cable with ferrite RI-14-28 (25MHz, 177W). The 'GND' output contact was grounded.
For the ESD test the flexible cable section (thin wires) and the probe head were sheltered inside the plastic protection tube delevered with the transducer.

 
Drawings:
 
Outline Detail YM12
E-Module Drawings
 Click on the above drawings for a printable pdf drawing.

 Specifications are subject to change without notice.
 Last updated on: 15 January, 2013
 
  Tel: + 650-802-8292    Fax: + 650-802-8298
   
Email:     
955 Industrial Road, San Carlos, CA 94070, USA