Senis Magnetic Field Transducers, CH3A  
Tabs
 
Specifications - CH3A Magnetic FieldTransducers
 Magnetic & Electrical
  System Part Number Symbol  CH3A2ME3A1-0.2T CH3A2ME3A1-2T Units Condition
  Maximum Full Scale Flux Density
-

±0.5
±3 T
No saturation of the outputs
  Linear range of magnetic flux density BLR ±0.2 ±2 T Optimal measurement range
  Accuracy - 1.0 % of BLR See note 1
 Output voltages VOUT differential V See note 2
  Sensitivity to DC magnetic fields S
50 5  V/T Differential output. see note 3
 Tolerance of sensitivity SERR <0.5 % of S 100x|S'-S|/S, see notes 3 & 4
  Temperature coefficient of sensitivity
-  <100 ppm/°C At 23°C ±10°C
  Non-linearity NL <0.1 <1.5 % of BLR B ≤ BLR, See note 4
  Planar Hall Voltage
VPLANAR

<0.01 % of VNORMAL See note 5
  Long-term instability of sensitivity - <1 % over 10 years  
  Voltage Offset VOFF <±5 <±3 mV B=0T
  Magnetic field offset BOFF <±0.1 <±0.6 mT B=0T
  Temperature coefficient of the VOFF - <0.5 <0.25   mV/°C B=0T
  Temperature coefficient of the BOFF - <0.1 <0.05 mT/°C B=0T
  Offset fluctuations -  <2 <0.5 mVPP Δt=0.05s, t=100s, see note 6
  Offset drift - - 0.1 mTPP Δt=0.05s, t=100s, see note 6
 Output resistance
 (short circuit protected)
- <10 Ω  
 Frequency response - DC to 2.5 kHz -3dB, see note 7
 Noise Spectral Density f=1Hz NSD1f ≈35 μV/√Hz  Region of 1/f noise
 Noise Spectral Density f=100Hz NSDW ≈10 μV/√Hz  Region of white noise
 Power - ±12V, 50mA -  
 Mechanical
  Electronics Module E Symbol E3D Units Condition
  Power connector - DIN SFV50, 5 pole mm  
  Singal output connector
- DIN SFV81, 8 pole mm  
  Dimensions
- 95W x 120L x 37H mm  
  Weight signal output cable
- 93 g/m  
  Case material - Aluminum -  
  Operating temperature
- +5 to +45 °C  
  Storage temperature - -20 to +85 °C  
 General
  Hall Probe Module H Symbol H Units Condition
  Dimensions - 4W x 2H x 16.5L mm  
  Weight H-Module - 2 g  
  Weight H-Module to E-Module Cable - 42 g/m  
  Field Sensitive Volume (Δx, Δy, Δz) - 0.15 x 0.01 x 0.15 mm  
  Center of the Field Sensitive Volume - 2.5 x 1.0 x -1.0 mm  
  Angular accuracy of the axes - ±0.5 ° Angle to the reference surface
  Cable length - 2 to 10 m  

Notes:
1. The accuracy of the transducer is defined as the maximum difference between the actual measured magnetic flux density
    and that given by the transducer.
2. The output of the measurement channel has two terminals and the output signal is the (differential) voltage between
    these two terminals.
3. Sensitivity is given as the nominal slope of an ideal linear function.
4. Nonlinearity is the deviation of the function Bmeasured = f(Bactual) from the best linear fit of this function.
5. The planar Hall voltage is the voltage at the output of a Hall transducer produced by a magnetic flux density vector co-planar with the Hall plate.
6. This is the 6-sigma peak-to-peak span of offset fluctuations with sampling time Δt = 0.05s and total measurement time t = 100s.

The below older model 3M12 have replaced by the newer model CH3A.
 Old Senis model  New Senis model
  3M12-2-2-0.2T
CH3A2ME3A1-0.2T
  3M12-2-2-2T
CH3A2ME3A1-2T

All specifications subject to change without notice.

 Last updated on 28 May, 2008
 
Site Map Search Powered byGoogle Legal Information Privacy Policy GMW Associates, Inc.
   
Tel: + 650-802-8292    Fax: + 650-802-8298
955 Industrial Road, San Carlos, CA 94070, USA