Specifications - 866 Current Transducers
 Electrical
  LEM Danfysik Model Symbol  IT 150-S   IT 600-S Units Condition
  Frormer Danfysik ACP Model   866-150  866-600 Units Condition
  Primary Nominal Current (peak)
Ipn

±150
±600
A

  Polarity - Bipolar -  
  Secondary Nominal Current Isn ±200 ±400 mA
 External Burden Resistor -
   Nominal for fs operation
   Min
   Max for Ipn< ±150A

Rb,max
Rb,min
Rb,150

5
0
95

2.5
0
95

Ω
Ω
Ω



  Transfer ratio (Ipn/Isn) N
750 1500 -
 Max nondestructive overload
 Min overload trip value
Ip,max
Ip,min
5.0x
1.1x
Ipn
Ipn
@ 0.1s

  DC Offset - Initial
            - Drift vs. Temp.
Iso
Iso, temp
<20
<0.2
ppm
ppm/°C
 
            - Drift vs. Time
            - Drift vs. Supply Voltage
Iso, time
Iso, supply
<1
<1.5
ppm/month
ppm/%
 
  DC Transfer ratio
         - Deviation
         - Deviation vs. Temp

Nd
Nd, temp

<2
<0.3

ppm
ppm/°C
 
  DC Linearity Deviation
Xd

<1

ppm


  Output noise rms Is, noise <0.01
<6
<20
<0.05
<3
<10
ppm (rms)
ppm (rms)
ppm (rms)
0-10Hz
0-10kHz
0-50kHz
  Dynamic resp. slew rate
dl/dt
>25 >100 A/µS
10-90%
  Bandwidth ±3dB* f 100 kHz <5% of Ipn
  Busbar induced voltage noise** Ub <10 µVrms DC-50kHz
  Busbar free zone within
  cylinder of diameter x length
dia.
l
150
150
mm
mm
Ipn, single conducto
  Test voltages (Busbar to GND) Vt,b
5000 VACrms  
  Power supply - voltage
    Max. quiescent current
    Max. current consumption
Vs
Iq
Imax
±15
±200
±600
V
mA
mA
±5%

 Operating environment.
   -Temperature.
   -Humidity

Ta
RHa

10 to 50
20 to 80

°C
%RH


Noncondensing
 Storage environment.
   -Temperature.
   -Humidity

Ts
RHs

-20 to 85
20 to 80

°C
%RH


Noncondensing
 Mechanical
  LEM Danfysik Model Symbol IT 150-S 866-600 Units Condition
  Busbar hole diameter d 25 mm  
  Width
W 122 mm  
  Height
H 98 mm  
  Depth
D 65 mm  
  Weight m 1 kg  

Notes:
* For 2.5Ω or 5Ω Burden Resistor, <5% of Ipn, Nd<±3dB, DC to f.
** Busbar noise measured on primary cable with one turn
All ppm figures refer to nominal current and transducer head programmed to maximum primary current.

All specifications subject to change without notice.

 This page was last updated on 20 September, 2010
 
Site Map Search Powered byGoogle Legal Information Privacy Policy GMW Associates, Inc.
   
Email:     Tel: + 650-802-8292    Fax: + 650-802-8298