Email: sales@gmw.com Telephone: USA +650-802-8292 Advanced Search 
 
HOME

PRODUCTS
Hall Magnetic Sensors
Magnetic Field
Electric Current
Angle & Position

Measurement Instruments
Electric Current
Electric Voltage
Magnetic Field
Magnetic Field Mapper
Magnetic Susceptibility

Fiber- Optic Links

Permanent Magnets

Electromagnets & Coils

Current Leads, HTS

Electromagnet Power Supplies

Particle Beam Diagnostics

Particle Beam Transport & Accelerators



• Special Sale Offers
• Discontinued Products

REQUEST HELP /  INFO



APPLICATIONS
TECHNICAL NOTES
CALIBRATION & SERVICE
CUSTOMERS
PARTNERS



GMW ASSOCIATES
Conference Schedule
News Items
About GMW
Contact Information
Employment at GMW
LEM Danfysik Current Transducer System, 866R  
Tabs
 
The 866R is no longer in production and has been replaced by the LEM IST. Please see Discontinued Products.
Specifications - 866R
 Electrical
  Primary Current (with 866-600 Head)
600A peak, 425A rms
  Polarity
Bipolar
  Output at Maximum Primary Current
    Current Output (screw terminals)
    Voltage Output (BNC connector)

± 400mA1
± 1V
  Load Capacity
    Normal Operation
    Overload (basic function maintained)
    Overload (fault)

100%
110%
500% (0.1s)
  Transfer Ratio Accuracy
    Current Output - I(max)A/400mA1
       dc
       to 1kHz
       to 10kHz

    Voltage Output - I(max)/1V
       dc
       to 1kHz
       to 10kHz


< 10ppm
< 500ppm
< 1,000ppm


< 1,000ppm
< 1,000ppm
< 1,000ppm
  Linearity
    Current Mode
    Voltage Mode

< 10ppm
< 30ppm
  Phase Shift
    to 1kHz
    to 10kHz

< 2 degrees
< 5 degrees
  Measuring Ratio Stability
      Current Mode
          Vs. Temperature
          Vs. Time
      Voltage Mode
          Vs. Temperature
          Vs. Time


< 1ppm/°C
< 1ppm/month

< 5ppm/°C
< 10ppm/month
  Offset
    Initial
    Vs. Temperature
    Vs. Time

< 50ppm
< 2ppm/°C
< 2ppm/month
  Noise Feedback to Main Conductor
    DC-100kHz (rms)

< 10µV
  Output Noise (rms)
     DC-10Hz
     DC-10kHz
     DC-50kHz

< 20ppm
< 50ppm
< 150ppm
  Slew Rate (Output, 10-90%)
³ 10kA/ms
  Bandwidth
    (5 ohm Burden Resistor, -3dB,
    small signal 0.5% of full scale)
DC to 100kHz
  Test Voltage (25mm dia. Busbar to Ground)
5kVAC (rms)
  Environmental Conditions
     Operating Temperature
       Electronics
       Transducer
       Humidity


10 to 50°C
0 to 60°C
20 - 80%
  Input Power Requirement
85 - 260Vac, 50/60Hz, 100VA
  Sensitivity to AC Input Change 2ppm/%
  Sensitivity to conductor position < 0.3ppm/mm
  Busbar Free Zone (single current return) Ø 150 x 150L
  Magnetic Field Coefficient
     Axial
     Radial

< 5ppm/mT (5mT max.)
< 5ppm/mT (5mT max.)
  Standards
     Emission Compliance
     Immunity Compliance

EN50081-2
EN50082-2-195
  Mechanical  
    Dimensions
      Electronics
      Weight

      Head
      Hole Diameter
      Weight (each)

483 x 88 x 250 (mm)
4kg

122 x 98 x 65 (mm)
Ø 26
1kg

Note 1: The 866R may be delivered factory programmed for the following currents defined in the 866R VOM selection chart.

All ppm figures refer to full scale output
All dimensions are in mm.
Specifications are subject to change without notice.

 This page was last updated on 26 May, 2011
    
 
Site Map Search Powered byGoogle Legal Information Privacy Policy GMW Associates, Inc.
   
Email:     Tel: + 650-802-8292    Fax: + 650-802-8298
955 Industrial Road, San Carlos, CA 94070, USA