Danfysik Current Measurement System, 862 
Tabs
 
Specifications - 862R
 Electrical
  Primary Current 7.5, 10, 16, 20, & 24kA
  Polarity
Bipolar
  Output Voltage (maximum)
0 to ± 10V (1)
  Output Current (maximum)
5mA
  Overload Capacity
   Normal Operation
   Basic Function Maintained
   Fault

100%
115%
300% (0.1s)
  Calibration (Absolute @25°C)
< 50ppm (2)
  Linearity
< 5ppm
  DC Accuracy
   Initial
     Vs. Temperature (typ)
     Vs. Temperature (max)
     Vs. Time
   Offset
     Initial
     Vs. Temperature
     Vs. Time


< 0.5ppm/°C
< 1ppm/°C
< 1ppm/month

< 5ppm
< 0.5ppm/°C
< 1ppm/month
  Output Noise (rms)
   DC-10Hz
   DC-1kHz
   DC-10kHz
   DC-50kHz

< 0.1ppm
< 0.5ppm
< 2ppm
< 5ppm
  Feedback Noise (rms)
   DC-100kHz (measured on the 
   primary current cable - one turn)
< 2µV
  Slew Rate
   (Output Voltage, 10-90%)
> 10 x I(fs)/ms
  Bandwidth
   (- 3 dB, small signal, 0.5%)
DC to 30kHz
  Test Voltage
    (Transducer Head)
10kVAC (rms)
  Operating Temperature
   Control
   Head

10 to 40°C
0 to 50°C
  Input power requirement
115 or 230 VAC, 50/60Hz, 150-250VA
  Busbar Free Zone
   (from center)
R > 70mm
  Conductor Position Sensitivity
< 0.3 ppm/mm
  Magnetic Field Coeff.
   Axial
   Radial

< 2 ppm/mT
< 5 ppm/mT
  Cable Length
   Standard
   Max

5m
30m (with reduced bandwidth)
 Mechanical  
  Dimensions
   Control (W x H x D)
   Weight

   Head

483 x 222 x 420
14kg

Please refer to the transducer
head drawings for dimensions
  Connectors  
   Front
    Test

 2.0mm pin jacks, shorting
   Rear
    Power

    Transducer
    Fine Control Input
    Status/Interlock Output
    Analog Output

 Schaff Power Line Filter with Voltage
 Select  and Fuse Holder. P/N FN 376-2
 D25, male
 D9, male
 D15, male
 D9, female

 Notes:
  (1) Full scale voltage outputs of less than ±10V are available on special order
       and at an additional cost.
  (2) Calibration accuracy of 25 ppm is available on special order and at an
       additional cost.

 All ppm figures refer to full scale output
 All dimensions are in mm.
 Specifications are subject to change without notice.
 
 